However, even under the best of circumstances, it will be a timeconsuming task with many traps and pitfalls for the. Now the shaft alignment measurement procedure can begin. If the front is farther out than the rear, that wheel has toeout. For example, consider the twowire connection of a strain gauge shown in figure 8a.
Shaft aligning procedure preliminary checks visually check coupling, pipe hangers, base bolts, coupling spacing etc. When mounting a dial indicator to the shaft or coupling to be measured, it is important to position the stem as close to perpendicular 90 relative to the surface being measured as possible. See more ideas about table saw, tools and woodworking. Insert the plug gauges in the holes which to be checked. Shaftline and main engine alignment onboard the procedure for doing reverse dial indicator alignment is not a difficult one. To determine vertical coupling gap difference, the face indicator is set to zero at a vertical position 12.
Dial indicator is a very important comparator used in mechanical industrial measurement applications. New, aftermarket tk14, tk15, tk24, tk25 cartridge carrier alignment and overhang tool. Check items before taking wheel alignment measurement. This course begins with the fundamental principles behind shaft to shaft alignment and concludes with students conducting a series of alignment exercises using conventional alignment tools. The skf tksa 11 is the first instrument on the market that uses inductive proximity sensors, enabling accurate and reliable shaft alignment to. Dial gauge alignment procedure in covered with detailed animation. Applications switch tip alignment place lasealign onto rail head aligning the relevant datum line 90mm or 255mm with bearer one toe stock rail bolt. Care has been taken by the authors, pruftechnik ltd, in the preparation of this publication. However, precision alignments are possible using dial gauges with magnetic bases. Toein alignment gauges pegasus auto racing supplies. In the right hands, a very accurate alignment can be performed with dial indicators. The face indicator is used to measure coupling gap differences.
A rough alignment is necessary due to the range limitations of the dial indicators. The original recommendations of the press manufacturer, if available, should always supersede the procedures described below. Three sizes of gages are available so that every model of rps laser probe can be. Dial indicator alignment basics alignment knowledge. Dial indicator principle, diagram, working, application. For maintenance personnel in drinking water and wastewater. A read is counted each time someone views a publication summary such as the title, abstract, and list of authors, clicks on a figure, or views or downloads the fulltext. For the alignment to be successful, both the equipment and the overall system must be property designed, and the installation must be well done. Vibralign is committed to helping businesses use their resources more efficiently and effectively.
The figures and equations in the previous section ignore the resistance in the lead wires of the strain gauge. Machine alignment for maintenance personnel in drinking water and wastewater facilities. Clean the depth micrometers measuring surfaces and the gauge blocks to be used. With the coupling broken, mount the fixture to the stationary shaft or coupling hub. Face dial indicator readings and angular misalignment the face dial indicator is mounted parallel to the shafts with the plunger making axial contact on a coupling hub. Working of dial indicator it operates on the principle, that a very slight upward pressure on the. Unitedstates departmentoftheinterior bureau of reclamation procedurefor calibratingdialindicators usbr 100789 introduction this procedure is under the jurisdiction of the geotechnical services branch, code d3760, research and laboratory services. It is desirable in an fm receiver to adjust all frontend and if amplifier circuits for maximum if signal to the limiting. At present man diesel recommended procedure prior to chocking is.
Townshend alignment gauge owners manual, service manuals and schematics are for reference only and the vinyl engine bears no responsibility for errors or other inaccuracies. Ensure fixtures are mounted at a position where rotation is possible. The rim dial indicator is used to measure offset in one plane along the shaft length and. To read a dial indicator, start by mounting it on a stand to stabilize it and calibrating the dial by turning the outer face until the hand points to 0. The graphical illustration of a single dial indicator sweep is. Dial indicators are an essential tool for maintenance pros. Vertical orientation alignment gages these alignment gages minimize alignment time by allowing probe alignments to be completed in two scan passes instead of the typical eighteen to thirtytwo scan passes required with a standard alignment ball. If you really want to significantly reduce your repair outage time, our concentricity alignment tool cat is exactly what you need. Shaft aligning techniques shaft alignment by conventional method shaft alignment by dial test indicator dti shaft alignment by using laser equipment shaft alignment by using computer. Proper alignment is the largest factor in determining the life of bearings, seals and couplings. Dial gauge must be securely mounted such as on a comparator stand or magnetic base. Use for any purpose other than measuring may damage or wear the instrument. A practical guide to shaft alignment plant services. This device is not universal since the receptacle for cartridge body without stylus holder has to be designed in accordance with respective cartridge body.
Reverse indicator method 10 alignment and couplings figure 25. Several equipment alignment methods, especially the reverse dial indicator method, which is the principle used in laser alignment is covered in explicit detail. Starting at zero on the gauge dial at the front of the vehicle, then moving the gauge to the back of the front wheels and setting the dial again, and taking a reading, makes this alignment procedure so easy that anyone can do it. How accurate are dial indicators for shaft alignment. Lower the scribe and bring the reference plane into good contact with the surface plate. Alignment procedure aline precision reverse alignment tools. Shaft alignment methods explained bright hub engineering. Note to view pdf files the latest version of the official acrobat reader is required. Alignment procedures the procedures and frequency for press alignment will vary according to the press design and condition and the quality control procedures of the plant. Measuring wheels as shown above the outside width is 88.
Hot alignment in the past, a hot alignment check may have been used to check the accuracy of the cold alignment procedure. A popular method used for years and is still in use today is the rim and face method. It is not intended as a comprehensive guide to alignment of process machinery, nor is it a substitute for seeking professional advice or reference to the manufacturers of the machinery. Permission is granted to copy, distribute andor modify this document under the terms of the gnu free documentation license, version 1. Since the pump shaft can not be turned when uncoupled and resting on the bottom, the laser readings were taken using the static measurement mode, which is a process that permits a reading to be taken in any cardinal or subcardinal position. Offset alignment or radial alignment is checked using a straight edge ruler. Toe is the difference between the distance from the front of one tire to the other, and the rear of one tire to the other. The difference between the top and bottom reading is the sag each time alignment reading is taken then the sag must be accounted for subtracting pump motor aligning the shafts centerlines from side to side the indicators are zeroed on the left and read at the right make sure that you always view the dti from pump side there is no sag. Rim and face alignment method are oldest method used for shaft alignment of misaligned equipmentshaft. If the front of the tire is closer to the centerline than the rear, the wheel has toein.
While ignoring the lead resistances may be beneficial to understanding the basics of strain gauge measurements, doing so in practice can be very dangerous. Locate the job on receiving gauge by locating pins. Total indicator reading ill zero my dial indicator at 12, and then roll it 180 degrees to 6. Townshend alignment gauge phono cartridge alignment gauge. Choose a scale for the horizontal line and plot accurately the distances 12, and 14 you measured previously. If the face dial contacts the coupling face directly, ensure the plunger of indicator contacts the coupling near its outer edge. Shaft laser alignment 3 benefits over dial indicators. Here you can download the pdf template of the tksa 20 shaft alignment report, which can be used for documenting of your alignment activities. Mounting a dial indicator dial indicator contact point screw thread section is standardized on m2. This video gives a brief overview of how dials can be used to measure shaft alignment, and can even be adjusted to. Clean the dial indicators measuring surfaces and stand, the granite plate, an d the gauge blocks to be used.
It is to note that none of the alignment is perfect. Shaft alignment training course ppt presentation and machine. This measurement will be made by using dial indicators that measure in 0. Standards and equipment used must have a valid calibration certificate. Fixturlaser dial indicator kit setup acoem youtube.
Coronavirus covid19 update we are now processing and dispatching orders again on a daily basis. Face dial indicator readings and angular misalignment. The shaft alignment training course provides a highly practical knowledge of the use of dial gauge in coupling alignment. Reference the dial indicator probe on the knuckle cap. Dial indicators are most commonly graduated in thousandths of an inch 0. Today im going to talk about 3 dial indicator concepts. Dec 22, 2014 shaft laser alignment 3 benefits over dial indicators lovejoy disc coupling being laser shaft aligned as discussed in prior posts, shaft misalignment is one the major causes of premature coupling, bearing, and seal failures in a power transmission system. Remove any contamination and clean the surface plate, gauge base, and scribe reference surface.
These steps are broken up for easier navigation on the web. Unfollow wheel alignment toe gauge to stop getting updates on your ebay feed. Due to reduced staff and restrictions that are in place in the uk and worldwide, there may be some delay in receiving your order. Shaft alignment with the new fixturlaser dial indicator kit is fast and easy when paired with the free fixturlaser dials app. However, factory tests have shown that the results of the hot alignment check are inconsistent. Step 4 precision alignment with a dial indicator youtube. Always return the gauge to its protective case when not in use. It is not intended as a comprehensive guide to alignment of process machinery, nor is it a substitute for seeking professional advice or. A wide variety of alignment gauge options are available to you, there are 249 suppliers who sells alignment gauge on, mainly located in asia.
Us patent 4,490,816 1984 invented by kehl and assigned to shure. Always change the sign of the dim values to compensate for reversed readings. Dial indicators are subject to rod sag, enough to throw off the measurement results. There are several steps which need to be taken for a successful alignment job. The plunger is a spring loaded part that can be depressed into the case causing the dial to move clockwise. Inspection check the following items before taking wheel alignment measurement. However our system is engine shaft is roatted and compressor shaft is stationary, as the coupling is fixed after carrying out the alignment procedure. Pdf a laser shaft alignment by ipspsds for rotary machine. Point 1 represents the position of the dial indicator 1, point 2 the dial indicator 2, point 3 the front of the motor, and point 4 the rear of. A laser shaft alignment by ipspsds for rotary machine article pdf available in international journal of engineering and technology 44. Rod sag is one of the reasons you may observe differences between dial indicator readings and laser reading. Incomplete thread section at the root of the screw shall be less than 0. In this method two dial indicator rim and face dial are used to determine the relative position of movable shaft with respect to stationary shaft. The purpose of this tutorial is to highlight important items that must be done prior to the final alignment adjustment, as well as to provide some details of the final alignment procedure.
Dial indicator alignment basics dial indicators are measuring devices designed expressly to measure relative position. Vemc presents pump motor alignment process with help of dial gauge method for accurate and smooth functioning of machines in your manufacturing units. Once the dial indicator is calibrated, press the spindle on the bottom against the item youre measuring. Reverse dial indicator alignment procedure pdf if you are looking for a quick way to see who keeps calling you late at night from an unrecognizable number, then our reverse phone lookup services can help. Adjust dial indiactor so anvil can be fully depressed without touching the gauge slide and tighten set screw in casting.
Alignment rotating equipment free download as powerpoint presentation. The procedure for doing reverse dial indicator alignment is not a difficult one. Manufacturer of the concentricity alignment tool cat. This means that all the alignments are rough alignments done with the help of a straight edge ruler or a filler gauges. Rating is available when the video has been rented. Dial indicator calibration procedure memorial university.
Again, reverse alignment is the measurement of one axis to the relative position of an opposing axis. The alignment training is suitable for technicians undertaking machine alignment, coupling alignment, motor alignmnet, pump alignment, etc. Check wheel alignment in minutes this tool measures toeout and toein on a simple to read gauge reads wheel wobble maximum distance from outside of tire to outside of other tire must be less than 81 easy to use. For vertical and horizontal rim readings, shaft offset is 12 of the total indicator reading tir. Make adjustments as needed to drop laser into the hole. Before obtaining alignment measurements, determine dial indicator bar sag of the rim dial. Use of product other than as described in the manual may cause accident. Check the indicated value, if reading is zero, then the zeropoint setting is complete. Often referred to as an electronic radial alignment gauge erag, we are the exclusive manufacturer of these tools. This method produces acceptable results, but is less accurate than the reverse dial indicator method covered in this application note. Your tk14 and more cartridge carrier fits into the jigtool so you can properly align the cartridgestylus and establish the correct overhang distance for the stylus. The primary parts of a dial indicator are the face or dial, the case, and the plunger.